Piping Connections
Gas Supply Pressure
The unit is equipped for a maximum gas supply pressure of 1/2 psi, 3 .5 kPa, or 14 IN WC .
NOTES:
Supply pressure higher than 1/2 psi requires the installation of an additional service regulator
external to the unit.
PRESSURE TESTING SUPPLY PIPING
• Test pressures
above
1/2 psi—disconnect the heater and manual valve from the gas supply line
to be tested. Cap or plug the supply line.
• Test pressures
below
1/2 psi—before testing, close the manual valve on the heater.
GAS CONVERSION
• Gas conversion kits are available for changing from propane to natural gas or natural gas to
propane. A factory-authorized conversion kit MUST be used.