Analog Output AO1
Fig. 7-12:
Analog output AO1
Code
Name
Setting Range
Default
Attri.
E2.25
AO1 output mode
0: 0...10 V
1: 0...20 mA
0
Run
E2.27
AO1 gain setting
0.00...10.00
1.00
Run
F2.04
Pressure command corresponding to 10
V / 20 mA
0.1...1,000.0 bar
10.0
Stop
F2.06
Pressure feedback corresponding to 10
V / 20 mA
0.1...1,000.0 bar
100.0
Stop
F2.08
Flow command corresponding to 10 V /
20 mA
1...3,000 rpm
400
Stop
F2.31
AO1 output
(use E2.27 for gain)
0: No function assigned from ASF
1: Pressure command (scaled by F2.04)
2: Pressure feedback (scaled by F2.06)
3: Setting speed (include direction)
(scaled by F2.08)
4: Output speed (include direction)
(scaled by F2.08)
0
Run
Tab. 7-6:
Analog output AO1 parameter list
The default setting of AO1 when connected to ASF is [F2.31] = 0, i.e. when
ASF is not active, the function of AO1 setting in EFC firmware is active.
AO1 and AI1 are recommended to be used for motor thermal pro‐
tection sensor (PTC), see
chapter 7.9.2 "Motor Thermal Protec‐
tion with Temperature Sensor" on page 129
.