6.4
Assembling the FcP System
6.4.1
Mechanically Connecting the Motor Pump Unit
Motor, pump, coupling and other mechanical components should be correctly
assembled. Make sure the motor pump unit assembling fulfill following condi‐
tions:
●
Assemble in dry, dust free environment.
●
Ensure a clean and burr-free machine-side contact surface.
●
Securely screw the motor-pump unit with the machine construction.
6.4.2
Hydraulically Connecting the Motor Pump Unit
●
Remove the flange covers on suction and pressure port.
●
Immediately wipe off any leaking oil.
●
Check the line for cleanliness.
●
Ensure that the line connection contains the specified sealings.
●
Lock O-rings with assembly grease against slipping , if necessary.
●
Now, hydraulically connect the pump according to the specifications of
the machine manufacturers.
Rexroth Sytronix Assembly and Maintenance Internal Gear Pump
PGH/PGM/PGF
●
Material number: R911340908 (Edition 02)
Rexroth Sytronix Mounting and Commissioning Axial Piston Variable Pump
A10VZO/A10VSO/A4VSO
●
Material number: R911341629 (Edition 02)
DOK-SYTROX-FCP5020****-IT01-EN-P
Bosch Rexroth AG
49/201
Frequency-controlled pump drive system Sytronix FcP 5020
Assembly and Installation