Code
Name
Setting range
Default
Min.
Attri.
F2.07
Pressure feedback null offset in V
or mA
0.0...5.0 V, mA
4.0
(mA)
0.1
Stop
F2.10
Pressure sensor type
0: Others
1: HM20-2X/10-C
2: HM20-2X/50-C
3: HM20-2X/100-C
4: HM20-2X/160-C
5: HM20-2X/250-C
6: HM20-2X/315-C
7: HM20-2X/400-C
8: HM20-2X/630-C
9: Other 4...20 mA pressure sensor
10: Reserved
11: HM20-2X/10-H
12: HM20-2X/50-H
13: HM20-2X/100-H
14: HM20-2X/160-H
15: HM20-2X/250-H
16: HM20-2X/315-H
17: HM20-2X/400-H
18: HM20-2X/630-H
19: Other 0...10 V pressure sensor
3
-
Stop
Tab. 7-4:
Parameter list of HM20 pressure sensor auto selection
The pressure conductor for hydraulic pressure control can be configured un‐
der "4: Pressure Feedback Configuration", there all Rexroth HM20-2X sensor
data have been saved and these can be directly selected from data bank, or
for other sensors, please set the sensor type to "9: Other current sensor" or
"19: Other voltage sensor", then modify the values in unit conversion.
Fig. 7-10:
Pressure sensor configuration
DOK-SYTROX-FCP5020****-IT01-EN-P
Bosch Rexroth AG
75/201
Frequency-controlled pump drive system Sytronix FcP 5020
Commissioning of Sytronix FcP 5020 System