Fig. 7-8:
Communication and input interface
Pressure command can be found in “Communication Input”, by clicking this,
the main dialog will be shown as the following figure, here the pressure com‐
mand source could be selected between one of the 3 options: fixed value,
analog input or master communication. And the green grid below “Analog In‐
put” shows the EFC IO terminal occupying, if customer moves mouse on it,
orange color means occupied and green means free. Under the “Mater Com‐
munication” there is a link for configuration the master communication, there
the communication protocol could be selected, however, the most configura‐
tion for bus communication should be done on the PLC master side, this is
not within the scope of this Operating Instructions.
Fig. 7-9:
Pressure command value setting
For the “Flow Command Value” configuration interface is similar as “Pressure
Command Value”, to be noticed is the already occupied analog channel will
not be shown in “Analog Channel Selection”. And “---” means no channel is
selected.
DOK-SYTROX-FCP5020****-IT01-EN-P
Bosch Rexroth AG
73/201
Frequency-controlled pump drive system Sytronix FcP 5020
Commissioning of Sytronix FcP 5020 System