Damage to the device!
NOTICE
Provide strain relief for the terminal connectors of the device in the control
cabinet or use the optionally available connection accessory HAS02.
HCS03.1E-W0070
View
Identifica‐
tion
Function 3‑phase operation
Function 1‑phase operation
(only HCS02.1E)
L1
Connection to supply mains (L1)
L2
Connection to supply mains
(L2)
Connection to neutral con‐
ductor supply mains
L3
Connection to supply mains
(L3)
n.c.
Connection of equipment grounding conductor of drive con‐
troller
Screw connection at connector
Unit
Min.
Max.
Tightening torque
Nm
1,5
1,7
Connection cross section
Stranded wire
mm
2
1,5
16
AWG
16
6
Occurring current load and minimum required
connection cross section
See technical data of device used (I
LN
and A
LN
)
Occurring voltage load
See technical data of device used (U
LN
or U
LN_nenn
)
Fig.5-4:
Function, Pin Assignment, Properties
HCS03.1E-W0100…W0210
View
Identifica‐
tion
Function
L1
Connection to supply mains (L1)
L2
Connection to supply mains (L2)
L3
Connection to supply mains (L3)
Connection of equipment grounding conductor of drive con‐
troller
Terminal block
Unit
Min.
Max.
Screw thread
M6
Tightening torque
Nm
5,5
6,5
Bosch Rexroth AG
DOK-INDRV*-HCS03******-IT01-EN-P
Rexroth IndraDrive Drive Controllers Power Sections HCS03
32/67