10
running in Expansion Channel mode
). If it doesn’t, press
INC
or
DEC
until you see
PRIMARY CHANNEL
. Press
ENTER
.
8. At the
Power Source?
screen, press
INC
or
DEC
to select
DC Power Supply
, then
press
ENTER
.
9. At the
Supply Current Limit?
screen, press
INC
or
DEC
to specify the current limit
appropriate for your DC power supply, then press
ENTER
. (Cutoff current should be
slightly less than the power source’s maximum output current capability. To protect
your power supply from damage, Dual PowerLab 8x2 will never draw more current
than you specify here, but charge current may not reach the preset or manually set
value.)
10.
At the
Low Sply Limit?
screen, press
INC
or
DEC
to specify the cutoff voltage,
then press
ENTER
. (Cutoff voltage should be about 50% lower than the power
supply’s nominal output voltage. Example: For a 24V power supply, set the cutoff
voltage to 12V. To protect your power supply, charging stops if the power
supply’s voltage drops below the value you set here.)
11. At the
Use Regenerative Discharge?
screen, press and hold the
BACK
button, as
this feature does not apply to DC Power Supply setup. You will be returned to the
User Preset menu. You have now successfully set Smart Power Management for
your DC power supply. Next, repeat the process for your Lead Acid battery.
12. Press
INC
+
DEC
(i.e., press both
INC
and
DEC
at the same time) to display the
Options menu (
Choose TASK?
).
13. Press
INC
or
DEC
until you see
Charger Options
, then press
ENTER
.
14.
At the
Power Source?
screen, press
INC
or
DEC
to select
Battery
, then press
ENTER
.
15.
At the
Battery Current Limit?
screen, press
INC
or
DEC
to specify the current
limit appropriate for your Lead Acid battery, then press
ENTER
. (Maximum
output current capability of Lead Acid batteries varies widely. Generally, a
standard flooded Lead Acid car battery might deliver 25A continuously and 50A
for short periods. An AGM style might not have any trouble delivering 50A
continuously without suffering substantially shortened life. To protect your battery
from damage, Dual PowerLab 8x2 will never draw more current than you specify
here, but charge current may not reach the preset or manually set value.)
16. At the
Bat. Low Cutoff?
screen, press
INC
or
DEC
to specify the cutoff voltage, then
press
ENTER
. (Cutoff voltage should be no lower than 11V for a 12V Lead Acid
battery. Lower cutoff will provide longer Dual PowerLab 8x2 operating time at the
expense of Lead Acid battery life. If you are using two 12V batteries in series for 24V
operation, Dual PowerLab 8x2 will automatically double the cutoff voltage you set
here. To protect your power supply, charging stops if the power supply’s voltage
drops below the value you set here.)
17. At the
Use Regenerative Discharge?
screen, press
INC
or
DEC
to enable or
disable this feature, then press
ENTER
into a battery power source during pack discharge cycles.
18. Press and hold the
BACK
button to return to the User Preset menu.
Smart Power Management setup is now complete. Repeat the above procedures for
both DPL channels. The next time you cycle power to the Dual PowerLab 8x2, it will
prompt you to select either DC Power Supply or Battery as the power source, but it will
use the settings you entered to manage power from the selected source.