10.0 NATURE AND FREQUENCY OF CLEANING, INSPECTION AND MAINTENANCE
To proceed with this operation:
• Wear appropriate clothing,
• Use only vacuum cleaners where possible,
• If the use of compressed air is forced: also wear masks, goggles, protective gloves and always close the sleeves with
elastic,
• Dispose of waste deposits and respecting the environment and laws.
It is FORBIDDEN to use jets of water or other liquids on the unit.
Water splashing generated by atmospheric pressure and pressure jets generated by pressure washer for industrial
cleaning are both seen as jets of water.
For a smooth operation and good maintenance of the machine, it is recommended to perform, by the technician, the
regular operations. Scheduled maintenance can be limited to a few interventions that can save you from UNDESIRED
STOPS DURING THE USE AND MUST BE PERFORMED IN COMPLIANCE WITH THE TERMS ESTABLISHED
OTHERWISE BY APPLICABLE RULES.
10.0.1BACTERIOLOGICAL FILTER REPLACEMENT
(USER) CODE 1067
- Open the door
- Unscrew the bacterial filter manually in a counterclockwise direction
- Install new filter in a clockwise direction
The new bacterial filter should be new and in its original envelope
10.0.2PINS LUBRICATION
(USER)
OF THE MECHANISM OF CLOSING BY THE USER
- Only use silicone spray
- Use the spray in small quantities in the direction of closing hinges
10.0.3WATER TANK CLEANING
(LICENSED TECHNICIAN)
Disconnect the network cable! Only authorized technicians!
Remove the fairing
Empty both tanks through the drain hose supplied
Unhook the springs that hold the tanks
Disconnect the tubes connected
Disconnect the wires connected paying attention to the colours
Remove the caps from the tanks
Wash carefully with water and mild detergent tanks. Rinse and dry carefully.
In case of persistent impurities, use for cleaning a dishwasher detergent tablet, chopped, and placed in tanks
with about 500 cc of warm water. Shake to try to remove the dirt residues.
Rinse thoroughly and dry carefully.
Be careful during reassembly of the original positions of the coloured wires.
To prevent algae growth or other deposits, empty both tanks if the sterilizer is not
used for more 'than three days! When the sterilizer is turned off, keep always the
door not completely closed
!
At the end check that everything is ok CHECK ACTUATORS.