OPERATING MANUAL FOR
RETIGO BLUE VISION
COMBI STEAMERS
61
ver. EN04/06/12
ERROR
WHAT HAPPENED
WHAT TO DO
Err 30
Waste steam temperature sensor
failure
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Please call your service company.
Err 31
Drain temperature sensor failure.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Please call your service company.
Err 32
Boiler temperature sensor failure.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Please call your service company.
Err 33
Cooking cabinet temperature sensor 2
failure – the lower one in 1221/2011
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Please call your service company.
Err 34
Core probe failure – core probe 1
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Please call your service company.
Err 35
Cooking cabinet temperature sensor 1
failure – the upper one in 1221/2011
Combi oven is blocked in all cooking modes.
Please call your service company.
Err 36
Core probe failure – core probe 2
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used temporarily in all
cooking modes. Core probe 2 cannot be used. Please
call your service company.
Err 40
Cooking cabinet thermal fuse (S1, S2)
or boiler thermal fuse (S3) triggered –
overheating protection.
Please call your service company.
Err 41
Cooling failure - electronics overheating,
temperature higher than 65°C.
An error message can be cancelled by pressing “ESC”.
Clean out the air filter.
Err 42
High temperature of boiler - temperature
higher than 120 °C.
Please call your service company.
Err 60-79
Electronic board failure
Please call your service company.
Err 80-91
Frequency converter failure
Please call your service company.
Err 95
Incorrect revolutions of the blower
If the problem persist, call professional service
Err 96
Gas has not ignited
Check whether the gas supply is on and repeat the
ignition process
Err 97
Bad flue exhaust (only in appliances of
the B
13
type)-valid for gas combi
steamers only
Backdraft – turn off low pressure ventilation
Err 100
System error
Please call your service company
Summary of Contents for vision
Page 1: ...T o u c h t h e f u t u r e ...
Page 62: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 62 ver EN04 06 12 NOTES ...
Page 63: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 63 ver EN04 06 12 NOTES ...
Page 64: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 64 ver EN04 06 12 NOTES ...
Page 65: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 65 ver EN04 06 12 NOTES ...