OPERATING MANUAL FOR
RETIGO BLUE VISION
COMBI STEAMERS
54
ver. EN04/06/12
15. Gas combi steamers
15.1 Gas burner ignition
The little flame behind the time symbol indicates the
gas burner function. If the flame is on, the burner is
working.
In the event that the gas burner is lit and goes out for
any reason or the flame cannot be ignited at machine
start-up, a sound will be made and a message will
appear on the display.
If this occurs, press the “OK” button. This means that
the service personnel recognizes the situation and a
new ignition attempt will be performed.
The most common cause of ignition failure is that the
main gas supply is shut off.
However, if the gas supply is open and the message
about ignition failure keeps appearing, call professional
service.
15.2 SAFETY INSTRUCTIONS for the gas
combi steamer service
It is strongly recommended that the gas combi
steamer electrical and gas connection, operation
activation, adjustments and all the service
actions are provided exclusively by a service engineer.
The service engineer is obliged to provide you with
information about activating the gas combi steamer and
its service, maintenance and inform you about improper
operations. These actions include particularly any
interference with the appliance under its cover except
the water filling through the hydraulic unit.
INSTRUCTION
• The gas combi steamer must be installed only in
accordance with generally accepted government
regulations and standards.
• In compliance with generally applicable legislation
and standards, the operator is obligated to ensure
proper operation activation and after that, at least once
a year, gas appliance operation inspection by the
service engineer.
Gas odor procedure
• close the gas inlet
• shut down the combi steamer
• open the windows
• extinguish any open fires
• do not handle electric switches and appliances
• call the Emergency service
Flue gases odor procedure
• shut down the combi steamer
• open the windows
• do not start the gas combi steamer and contact
the service engineer
Procedure in case of flooding
• close the gas inlet
• shut down the combi steamer
• disconnect the electrical power supply
• do not start the gas combi steamer and contact
the service engineer
Procedure in case of a fire
• close the gas inlet
• shut down the combi steamer
• disconnect the electrical power supply
Summary of Contents for vision
Page 1: ...T o u c h t h e f u t u r e ...
Page 62: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 62 ver EN04 06 12 NOTES ...
Page 63: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 63 ver EN04 06 12 NOTES ...
Page 64: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 64 ver EN04 06 12 NOTES ...
Page 65: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 65 ver EN04 06 12 NOTES ...