26
parameters and defaults
Numero
Nome
Descrizione
Default
User
1
GKP
Proportional gain
100
2
GKD
Derivative gain
0
3
GKI
Integrative gain
0
4
GIL
Integrative limit
0
5
GKF
Tracking diameter gain
0
6
ACC
Acceleration stop-auto
10
7
DEC
Deceleration auto-stop
10
8
VMI
Minimum correction speed
10
9
VMA
Maximum correction speed
127
10
TYP
Sensor type
0
11
SPA
Set point in automatic mode
10
12
SPB
Set point dancer roll
50%
13
SPS
Set point in manual mode
20
14
SPF
Set point diameter
50%
15
SPE
Set point in emergency mode
40
16
TXL
X-Lo tension
0 (*)
17
TYL
Y-Lo tension
0,0 (*)
18
TXH
X-Hi tension
223 (*)
19
TYH
Y-Hi tension
100,0 (*)
20
DXL
X-Lo diameter
280 (*)
21
DYL
Y-Lo diameter
0,460 (*)
22
DXH
X-Hi diameter
589 (*)
23
DYH
Y-Hi diameter
1,840 (*)
24
ALR
Alarm level
199,9
25
DIS
Avg. Display
4
26
DIG
Digits number
1
27
INP
Input selection
0000
28
OUT
Output selection
02
29
ADR
RS-485 address
0
30
INI
Initial screen
0
31
LNG
Language
1
32
PWD
Password
0
33
TXT
Text on initialisation
Renova-srl.it