18
9 = Remote Display
Default:
0
LNG – Language
Usage:
Language of menu.
Description:
This field sets the preferred language in the text menu.
Range:
0 … 3
0 = Italian
1 = English
2 = French
3 = Spanish
Default:
1
PWD – Password
Usage:
To protect the setting of parameters.
Description:
When this parameter is set to a value (different to zero), the operator is asked a (fixed) password
to enter to parameters. Value 0 means no password required.
Range:
0 … 32767
Default:
0
TXT – Text on initialisation
Usage:
Text shown on the initialisation screen.
Description:
This parameter lets the operator to enter a specific string of characters to be shown during the
system initialisation screen.
Range:
Fourteen characters
Default:
“Renova.it”
remote interactions of a single unit
The RS-485 serial communication allows to control a second unit ISOMATIC from a remote location, using another
ISOMATIC.
By connecting a Isomatic to another Isomatic, the device can operate like an additional user interface. Let’ s explain
this application by an example. Let’ s consider a Isomatic, called “1”, connected to load cells and brake; consider then
another Isomatic, called “2”, to be used as a remote interface. By setting the INI parameter of the Isomatic “2” to 9
(INI = 9) and connecting the two devices like on the following figure, it is possible to use the keyboard and the display
of the Isomatic “2” like if they were the keyboard and the display of the Isomatic “1” (in other words, the user can use
either the keyboard and the display of the Isomatic “1” or “2”).
Note: in this type of application the Isomatic “2” works only like a clone of the Isomatic “1”. Example: if the GKP
parameter is changed from the Isomatic “2”, the parameter that is actually changed is the GKP parameter stored into
the Isomatic “1”.