19
Note: to have back the Isomatic “2” working as a tension control system (and not like a remote display), it is necessary
to set INI = 0. To enter in local parameters (of “Isomatic 9000 number 2”) it is necessary to press the Esc key during
the initialization phase (welcome screen).
MULTIPLE REMOTE CONTROL (MAX 31 UNITS)
To work with remote control, it is necessary to link all the units with a RS-485 net (CN 105) and to connect one
external switch (button) to the terminals 1 and 2 of the CN 102 of the command unit.
To work like Isomatic command unit it’s necessary to set the following parameters:
INI = 9 (Remote display)
ADR = 1…31 (Max number of external units)
INP = 1 (External button enabled)
To enter local parameter press ESC during the start up screen.
To work like Isomatic remote slave unit it is necessary to set the following parameters:
INI = 0…8 (according to the desired starting screen)
ADR = 1…31 (for each connected Isomatic a different sequence number must be entered).
By pressing the external contact of the command unit it can be selected the element to control. Alternatively the