14
Valore
Descrizione
0
Load cell
1
Dancer roll (potentiometer)
2
Ultrasonic sensor (detector diameter)
Range:
0 … 2
Default:
0
SPA – Set point in automatic mode
Usage:
Set the desired value of tension (tension setpoint).
Description:
This parameter stores the value of the desired tension.
Range:
0 … 199,9
Default:
10,0
SPB – Set point dancer roll
Usage:
Set the potentiometer setting.
Description:
This parameter stores the default value of the potentiometer (dancer roll).
Range:
0 … 100%
Default:
20
SPS – Set point in stop mode
Usage:
Set the default value of the command output in stop mode.
Description:
This parameter stores the default value of the command output in stop mode.
Range:
0 … 199
Default:
20,0
SPF – Set point diameter
Usage:
Defines the percentage of braking
Description:
This parameter stores the percentage of braking for a specific diameter of coil.
Range:
0 … 100
Default:
50 %
SPE – Set point in emergency mode
Usage:
Set the default value of the command output in emergency mode.
Description:
This parameter stores the default value of the command output in emergency mode.
Range:
0 … 100
Default:
40