13
Description:
This value is used to limit the integrative part of the correction needed to compensate the
measured error.
Range:
0 … 32767
Default:
0
GKF – Tracking diameter gain
Usage:
tracking diameter gain factor
Description:
This gain factor is used to calculate the correction in relation to the diameter of coil.
Range:
0 … 255
Default:
0
ACC – Acceleration
Usage:
Acceleration of correction motor
Description:
This value sets the acceleration of the brake or motor in automatic mode.
Range:
0 … 999
Default:
10
DEC – Deceleration
Usage:
Deceleration of correction motor.
Description:
This value defines the deceleration of the brake or motor in automatic mode.
Range:
0 … 999
Default:
10
VMI – Minimum correction speed
Usage:
Minimum correction speed.
Description:
This field specifies the minimum speed to apply to the correction motor. It permits to eliminate
the inertia of the correction motor.
Range:
0 … 127
Default:
10
VMA - Maximum correction speed
Usage:
Maximum correction speed.
Description:
This field specifies the maximum speed to apply to the correction motor. It permits to eliminate
the over correction of the error.
Range:
0 … 127
Default:
127
TYP – Type of sensor
Usage:
Shows the type of sensor used
Description:
This parameter allows to select the sensor you are using.