When this function is enabled (door open), all access codes (user codes and the
superuser code) will be temporarily disabled.
e) Enabling the access block with the superuser code
The relay opens when you enter a user/guest/temporary code. In certain circumstances, it may
be necessary to temporarily block the relay to prevent access without having to delete the codes.
The superuser code can be used to block access to the secure area at certain times, e.g. outside
office hours.
This function only affects the door opener relay. The door opener button (connected to
the "EG IN" terminal (7)) functions just like the superuser code, which allows the code
owner to control the relay.
To block access with the superuser code, proceed as follows:
2 5
8 0
#
9
Enter the superuser code (in this example, the superuser code is "2580")
and press the # key. Press "9" to confirm your entry.
When the access block is enabled, the relay is locked and cannot be
activated by user codes. The red LED stays constant when the access
block is enabled.
To disable the access block, enter the superuser code, press the # key, and
then press "9" to confirm your entry. The access block will be disabled and
the red LED will switch off.
When the access block is enabled, you can still use the superuser code to open the
door and access the secure area .
f) Opening the door opener with a guest code
Single-use guest code
1 2 3 4
#
Enter the guest code (in this example, the guest code is "1234") and press
the # key to confirm your entry.
The green LED will turn on when the door is unlocked. The code can only
be used once and is automatically deleted when the door is unlocked.
75