2.3
RMI-QE basics
RMI-QE visual diagnostics
A visual indication of system status is provided by LEDs. Status is continuously updated and indication
is provided for:
•
P1, P2, P3, P4 SYSTEM STATUS;
•
LOW BATTERY/START;
•
PROBE STATUS;
•
ERROR;
•
SIGNAL CONDITION.
Magnetic label
A summary of RMI-QE activity is provided on a magnetic label. The label may be placed on any
machine flat metal surface.
SIGNAL LED
P1, P2, P3, P4 SYSTEM STATUS LEDs
LOW BATTERY/START LED
ERROR LED
PROBE STATUS LED
NOTE:
Keep the front cover clean. All four lower LEDs flashing indicates a wiring fault or output
overcurrent.
abcdh
SIGNAL LED
Off
No probes
operating
Good
communications
Poor
communications
Overload error
KEY TO THE SYMBOLS
Continuously on
Flashing
ERROR LED
Off
No error
Error
System error
See installation
guide
Overload error
LOW BATTERY/START LED
Off
Battery is okay
and no M-code
start/stop in
progress
Battery low
M-code start/
stop in progress
Battery low and
M-code start/
stop in progress
Overload error
PROBE STATUS LED
Probe triggered
Probe seated
System error
See installation
guide
Overload error
P1, P2, P3, P4 SYSTEM STATUS LEDs
Off
Probe number empty
Probe number full, in standby
Probe number full, operating
System error
See installation guide
Selection error
Partnering/clearing pending, full
Partnering pending, empty
Partnering complete, probe full
Probe authentication error
Clearing complete, probe empty
Summary of Contents for RMI-QE
Page 1: ...RMI QE radio machine interface Installation guide H 6551 8520 01 A...
Page 6: ...RMI QE installation guide iv Contents This page is intentionally left blank...
Page 26: ...RMI QE installation guide 2 16 RMI QE basics This page is intentionally left blank...
Page 44: ...RMI QE installation guide 3 18 System installation This page is intentionally left blank...
Page 48: ...RMI QE installation guide 4 4 Maintenance This page is intentionally left blank...
Page 53: ......