RMI-QE installation guide
3.10
System
installation
Deflect the stylus for less than 4 seconds,
to select
“Partnering mode active”
.
Ensure this is done within 60 seconds of
the RMI-QE system status LED flashing
green.
SYSTEM STATUS LED
RMI-QE in “
Partnering mode
”
with empty probe location
SYSTEM STATUS LED
RMI-QE in “
Partnering mode
”
with full probe location
or
RMI-QE
SYSTEM STATUS LED
Partnering pending
RMI-QE
> 20 s
The probe is now in standby
and the system is ready for use.
SYSTEM STATUS LED
New radio probe partnered
or
SYSTEM STATUS LED
Radio probe cleared from location
Displayed for 5 seconds
Partnering mode
Active
20 seconds
probe in standby
Partnering
successful
If partnering is unsuccessful “
Partnering mode off
” will be displayed again after 8 seconds.
When
“Partnering mode off
(
RMI-QE
found)” is displayed, deflect the stylus for less than 4 seconds
to select “
Partnering mode active
” again.
Partnering mode
Off
(
RMI-QE
found)
> 20 s