RMI-QE installation guide
2.8
RMI-QE basics
RMI-QE output waveforms
RMI-QE
SSR/driven
outputs
Probe status 1
(level)
Probe status 1
(pulsed)
Normally open
Normally open
PROBE
SSR open
SSR open
SSR closed
SSR closed
Probe in
standby
Probe
switch on
Seated
Probe
trigger
Triggered
Seated
Probe
reseat
Error
for example
blocked signal
Low
battery
Probe
switch off
PROBE
RMI-QE
SSR/driven
outputs
Probe
switch on
Seated
Probe
trigger
Triggered
Seated
Probe
reseat
Error
clear
Low
battery
Probe
switch off
Probe status
2a/2b
(level)
Normally low
Output high
SSR open
SSR closed
Error
Normally
closed
Error
clear
Probe in
standby
Low battery
Normally open
SSR open
SSR closed
Output low
Probe
status 2a/2b
(pulsed)
Normally low
Output high
Output low
SIGNAL DELAYS
1.
Transmission delay
Probe trigger to output change of state
=
5 ms variation ±1 µs.
(Enhanced trigger filter off)
2.
Start delay
Time from initiation of start signal to valid signal transmission = 1 second max.
(Standard turn on mode)
NOTE:
Pulsed outputs are 40 ms ±1 ms duration.
Error
for example
blocked signal
Summary of Contents for RMI-QE
Page 1: ...RMI QE radio machine interface Installation guide H 6551 8520 01 A...
Page 6: ...RMI QE installation guide iv Contents This page is intentionally left blank...
Page 26: ...RMI QE installation guide 2 16 RMI QE basics This page is intentionally left blank...
Page 44: ...RMI QE installation guide 3 18 System installation This page is intentionally left blank...
Page 48: ...RMI QE installation guide 4 4 Maintenance This page is intentionally left blank...
Page 53: ......