RMI-QE installation guide
3.16
System
installation
Fitting the cable and conduit to the bulkhead
CAUTION:
The cable and conduit must be fitted to the bulkhead in the correct sequence, as described
below, as the conduit cannot rotate.
Conduit
Grommet
Straight
conduit fitting
Bulkhead
conduit fitting
1
1. Screw the straight conduit fitting into the conduit until finger-tight.
2. Fit the grommet over the cable in between the straight conduit fitting and the bulkhead conduit
fitting.
3. Screw the bulkhead conduit fitting onto the straight conduit fitting using the pin spanner provided
to hold the straight conduit fitting and a 32 mm A/F spanner to tighten, making sure that the
grommet is fitted to the cable, in the position as shown in Figure 1. Torque to between 3.0 Nm and
4.0 Nm (2.21 lbf.ft. and 3.0 lbf.ft.).
2
4. Fit the O-ring into the recess in the bulkhead conduit fitting.
O-ring
32 mm A/F
3.0 Nm – 4.0 Nm
(2.21 lbf.ft – 3.0 lbf.ft)