3.9
System
installation
The probe partnering function enables the radio probe to be partnered with the RMI-QE independently
of the configuration process for other probe settings. Refer to your relevant radio probe installation
guide.
To manually partner a single probe or tool setter with the RMI-QE proceed as follows:
Key to the symbols
LED short flash
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
To exit, leave the stylus untouched for
more than 120 seconds.
Partnering successful. Probe is now in
standby.
Battery status
Battery good
or
Battery low
All probe settings will be shown, ending
with “
Battery status
” being displayed.
1
> 5 s
2
3
Partnering mode
Off
Switch on the RMI-QE
120 seconds probe in standby if
RMI-QE is turned off
LED check
RMI-QE
Battery status
Battery good
or
Battery low
Whilst the “
Battery status
” is being displayed, deflect and
release the stylus to enter “
Partnering mode
”. Probe status
will flash red to acknowledge this.
At this point turn on the RMI-QE.
NOTE:
Wait until the first battery status flash has occured
before deflecting the stylus, and then release the stylus when
the red flash is observed. Ensure this is done before the last
battery status flash is displayed.
Summary of Contents for RMI-QE
Page 1: ...RMI QE radio machine interface Installation guide H 6551 8520 01 A...
Page 6: ...RMI QE installation guide iv Contents This page is intentionally left blank...
Page 26: ...RMI QE installation guide 2 16 RMI QE basics This page is intentionally left blank...
Page 44: ...RMI QE installation guide 3 18 System installation This page is intentionally left blank...
Page 48: ...RMI QE installation guide 4 4 Maintenance This page is intentionally left blank...
Page 53: ......