20
System installation
HPGA rear exit installation using
TSI 3 (or TSI 3-C) and HSI interfaces
TSI 3 (or TSI 3-C)
connector (6 way)
NOTES:
1. When the SSR is connected as normally open (N/O), the
MP250 will remain in the non-triggered (seated) state if the power
supply is interrupted or if the probe is damaged.
2. The TSI 3 (or TSI 3-C) interface will show a probe open condition whatever the
status of the MP250 probe. For this reason the TSI 3 (or TSI 3-C) interface probe output
must be ignored and the probe status from the HSI interface used.
3. The HSI probe output remains active in the machine ready position. To disable the
probe output use the HSI inhibit function (refer to page 28).
4 N/C
2 Screen
3 Probe - White
1 Probe + Brown
6 Motor - Grey
5 Motor + Red
HSI connector
(3 way)
Green 1
Yellow 2
Screen 3
3 way connector
Probe
dependent
1 Probe input 0 V
2 Probe input 5 V
3 Screen
1 Probe input +
2 Probe input -
3 Screen
LP2
MP250
44.5
Ø14.8
M12
Ø12
View A
1
8
7
6
5
4
3
2
Hub and
base
MP250
LP2
Pin
Screen
1
2
3
4
5
6
7
8