5.3 Component “ELCL multiple parameter monitoring”
Figure 5-4 shows the component “ELCL multiple parameter monitoring” and Table 5-3 shows the options for
this component.
Figure 5-4 Component "ELCL multiple parameter monitoring"
Output E
Checkbox
Table 5-3 Choices of component "ELCL multiple parameter monitoring"
Item
Choices
Description
Checkbox
Check: Input factor is valid
Uncheck: Input factor is invalid (Low level Clamp)
Select valid / invalid (Low
level Clamp) input factor
Source A
ELISEL_0 -
11
Note 1
Signals listed in Table 5-4, Table 5-5,
Table 5-6
Select an input factor
Source B
Source C
ELISEL_6 -
11
Note 1
Signals listed in Table 5-4, Table 5-6
Source D
Output E
INTELCL
Select the output
destination
DTC startup Trigger
SMS startup Trigger
A / D converter hardware trigger
D / A converter 0 hardware trigger
D / A converter 1 hardware trigger
CTSU hardware trigger
ITL capture Trigger
Note 1. ELISEL_0 - 11 and ELISEL_6 - 11 correspond to ELISEL0 - 11 and ELISEL6 - 11, respectively.
Note 2. Source A, B must select the input factor and select ELISEL_0 - 11 to link the input factor.
Similarly, Source C, D must select ELISEL_6 - 11. Refer to Table 5-4 to Table 5-6 and make the
correct settings. If the selected combination is incorrect, a warning will be displayed.