R11UM0156EJ0240 Rev.2.40
Page 30 of 82
Jul. 28, 2020
PRIME v1.4 Base Node Tool
User Manual
Renesas Electronics Group Confidential
3
.
PC Tool operation procedure
PRELIMINARY
Notice This is not a final specification. Some
parametric limits are Subject to change.
3.6.2.2
AppEmu cycle test data
Table 3-6 shows the execution of each step in AppEmu cycle test by the PRIME network version. For
PRIME v1.4 and v1.3.6 network all steps are executed. For PRIME v1.4 BC network, some data
transmissions in Step 4 and 5 are skipped. Because the maximum payload size of PHY type BC frame
for PRIME v1.4 BC is 76 bytes, the large data cannot be transmitted. Although BN tool uses BC mode:
“On (v1.3.6)” for v1.3.6 network, it does not use any robust modulations (DBPSKR-R and DQPSK-R)
and the maximum payload size of the frame is large enough to transmit data for all steps.
Table 3-6 The execution of each step by the PRIME network.
Size of packet
payload [bytes]
Execution of the step
request
response
v1.4
(BC mode: Off)
v1.4 BC
(BC mode: On)
v1.3.6
(BC mode: On
(v1.3.6))
Step 2
24
36
Yes
Yes
Yes
Step 3
24
31
Yes
Yes
Yes
Step 4
75
138
Yes
No
Yes
16
52
Yes
Yes
Yes
Step 5
17
17
Yes
Yes
Yes
29
29
Yes
Yes
Yes
65
65
Yes
No
Yes
137
137
Yes
No
Yes
209
209
Yes
No
Yes