background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Convection Heater User's Manual

Operation

Pre-Lighting Instructions:

Connecting the LP Cylinder

ALL NEW LP CYLINDERS MUST BE PURGED 

BEFORE THE FIRST FILLING.

 

Turn heater gas valve knob and LP cylinder 

valve to OFF position.

 

LP cylinder valve equipped with old style 

fitting has LEFT HANDED THREADS. Turn 

fitting CLOCKWISE to loosen. Protect this 

fitting when disconnected from LP cylinder.

 

Have your LP cylinder filled by your local 

propane gas supplier.

 

Some LP cylinders have a bleed-OFF valve. 

This valve should be inspected for leaks after 

each filling of the LP cylinder. Turn the valve 

clockwise to close.

 

Fasten full propane tank and connect 

proper fitting to LP cylinder valve by turning 

COUNTER-CLOCKWISE. (See figure 6 & 7)

 

With heater gas valve knob still in OFF 

position turn ON the LP cylinder valve and 

check for leaks with soap solution.

Checking For Leaks

 

To check for leaks, make up a 50/50 solution 

of dish soap and water. Apply this solution 

to all gas connections. If bubbles appear, 

there is a leak. If a leak is found, turn off 

the gas supply, and re-connect the leaking 

connection. If the leak persists after several 

tries, contact Pinnacle Customer Service at 

(800) 676-1989.

 

The installation of this heater must meet all 

local codes and/or gas utility requirements. In 

the absence of local codes, the National Fuel 

Code ANSI Z223.1 should be followed.

 

The minimum clearances to any combustible 

construction materials must be maintained at 

all times (See Page 2).

 

Inspect the heater before each use, and at 

least annually by a qualified service person.

Purging and filling of the 

LP cylinders must be 

performed by personnel who have been 

thoroughly trained in accepted LP gas 

industry procedures. Failure to follow these 

instructions may result in explosion, fire, 

severe personal injury or death. 

WARNING

Supply Valve

Regulator

Hose

Propane Tank

 Figure 6

 Figure 7

Hose

Inlet 

Connector

7

Summary of Contents for REM-200V-LPC-O

Page 1: ...THE MANUFACTURER DANGER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INS...

Page 2: ...nd approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other st...

Page 3: ...NDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...a from the heater and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect th...

Page 5: ...e 2 Specifications Model REM 80V LPC O REM 200V LPC O BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...from inside the heater See Figure 4 2 Remove all packaging protecting the heater during shipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Attach three 3 screws to...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on...

Page 8: ...ition turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connecti...

Page 9: ...SE to close it REM 200V LPC O 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from th...

Page 11: ...time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for ade...

Page 12: ...R UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2017 Pinnacle Climate Technologies Inc Convection Heater User s Manual Exploded View 11 Figure 8 REM 80V LPC...

Page 13: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for pr...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...