background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Convection Heater User's Manual

Lighting Instructions:

REM-80V-LPC-O

1. 

STOP! Read all of the safety information 

provided with this heater.

2. 

Turn valve on propane cylinder 

COUNTERCLOCKWISE until fully open.

3. 

Press in control knob and turn 

COUNTERCLOCKWISE to 

LOW/IGN 

position.

4. 

If burner does not ignite, turn control knob to 

OFF 

position and repeat the ignition procedure.

5.  Keep control knob pressed in for approximately 

30 seconds before releasing.

6. 

If the flame goes out, wait 5 minutes and 

repeat the ignition and lighting steps.

7. 

After heater ignites, turn the control knob to 

desired heat setting.

Relighting Instructions

1. 

Rotate valve on cylinder 

CLOCKWISE

 to close 

it and wait 5 minutes.

2. 

Relight following the Lighting Instructions, 

steps 1-7.

Shut Down Instructions

1. 

Turn control knob to the 

OFF 

position.

2. 

Rotate valve cylinder 

CLOCKWISE

 to close it.

REM-200V-LPC-O

1. 

STOP! Read all of the safety information 

provided with this heater.

2. 

Turn valve on propane cylinder 

COUNTERCLOCKWISE until fully open.

3. 

Set control valve to 

LIGHT/LOW 

position, 

then wait 15 seconds before step 4.

4. 

Depress the red button on the safety valve, 

admitting gas to the burner. While pressing 

the safety valve, push and release the ignition 

button until the burner lights. 

5.  When the burner lights, continue to keep the 

red safety valve depressed for 30 seconds 

then release. 

6. 

If burner goes out, wait 5 minutes and repeat 

lighting procedure. 

7. 

When burner lights, you can now adjust the 

heat setting to 

HIGH

 

by sliding the control 

valve up to the 

HIGH 

setting. 

NOTE:

 When adjusting heat setting, the control 

valve only needs to slightly slide up to achieve 

HIGH

 setting.

Relighting Instructions

1. 

Rotate valve on cylinder 

CLOCKWISE

 to close 

it and wait 5 minutes.

2. 

Relight following the Lighting Instructions, 

steps 1-7.

Shut Down Instructions

1. 

Rotate valve cylinder 

CLOCKWISE

 to close it.

Operation

EXTREMELY HOT during operation. Do Not touch any metal components while in 

operation. Keep gasoline and any other flammable liquids away from the heater.

WARNING

8

Summary of Contents for REM-200V-LPC-O

Page 1: ...THE MANUFACTURER DANGER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INS...

Page 2: ...nd approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other st...

Page 3: ...NDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...a from the heater and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect th...

Page 5: ...e 2 Specifications Model REM 80V LPC O REM 200V LPC O BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...from inside the heater See Figure 4 2 Remove all packaging protecting the heater during shipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Attach three 3 screws to...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on...

Page 8: ...ition turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connecti...

Page 9: ...SE to close it REM 200V LPC O 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from th...

Page 11: ...time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for ade...

Page 12: ...R UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2017 Pinnacle Climate Technologies Inc Convection Heater User s Manual Exploded View 11 Figure 8 REM 80V LPC...

Page 13: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for pr...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...