NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Convection Heater User's Manual

Ventilation

 

Risk of indoor air pollution and Carbon 

Monoxide Poisoning. Use heater only in 

well ventilated areas.

 

Refer to Safety Information on pages 1-2 

for information about Carbon Monoxide 

Poisoning.

 

ALWAYS

 provide a fresh air opening in the 

heated space of at least three square feet 

(2,800 sq. cm) for each 100,000 BTU / Hr. 

of heater output. Provide a larger opening if 

more heaters are being used.

Minimum Ventilation Opening Needed

80V-LPC-O

200V-LPC-O

2.4 ft.

2

6.0 ft.

2

2220 cm

2

5570 cm

2

CARBON MONOXIDE POISONING MAY LEAD TO DEATH!

DANGER

Not for use in residential 

living areas or in  

non-adequately ventilated enclosed spaces. 

DANGER

Storage / Maintenance

Always disconnect the heater from the LP 

cylinder before putting the heater into storage. If 

for any reason the heater is to be stored indoors, 

the tank MUST be disconnected from the LP 

cylinder, and the cylinder stored outdoors in a 

well-ventilated area, out of the reach of children, 

and in accordance with the Standard for Storage 

and Handling of Petroleum Gases, ANSI/NFPA 

58 - latest edition and Natural Gas and Propane 

Installation Code, CSA B149.1. The plastic valve 

plug or valve cover supplied with the cylinder 

must be re-installed on the valve to protect the 

fitting from damage.

NOTE: Installation and repair of this heater 

should be done by a qualified service person.

ALWAYS 

be sure to follow proper maintenance 

procedures. This should include cleaning the 

inside of the heater once a month and checking 

the spark gap at least once a heating season. 

Re-gap the terminals to 0.195” (4.9 mm).

Never store an LP cylinder 

inside of a building or near 

any other gas or oil burning appliances.

DANGER

9

Summary of Contents for REM-200V-LPC-O

Page 1: ...THE MANUFACTURER DANGER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INS...

Page 2: ...nd approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other st...

Page 3: ...NDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...a from the heater and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect th...

Page 5: ...e 2 Specifications Model REM 80V LPC O REM 200V LPC O BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...from inside the heater See Figure 4 2 Remove all packaging protecting the heater during shipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Attach three 3 screws to...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on...

Page 8: ...ition turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connecti...

Page 9: ...SE to close it REM 200V LPC O 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from th...

Page 11: ...time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for ade...

Page 12: ...R UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2017 Pinnacle Climate Technologies Inc Convection Heater User s Manual Exploded View 11 Figure 8 REM 80V LPC...

Page 13: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for pr...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: