background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Convection Heater User's Manual

Operation

Propane Supply / Information:

Propane (LP)

This heater is not supplied with a propane cylinder. 

Use only an approved propane cylinder.

LP Characteristics

 

Flammable, explosive under pressure, heavier 

than air and pools in low areas.

 

In its natural state, propane has no odor, but 

for your safety an odor that smells like rotten 

cabbage has been added.

 

Contact of propane (LP) gas with the skin can 

cause freeze burns.

 

Heater is manufactured for use with propane 

gas only. DO NOT attempt to convert to any 

other gas. Such modifications are dangerous 

and will void the warranty.

 

When heater is not in use, LP Cylinder must be 

turned OFF.

 

Be sure that the LP Cylinder is located on a 

level and stable surface.

 

DO NOT use this heater in a basement or 

below ground level. Propane is heavier than 

air and will always seek the lowest level. If you 

suspect a leak, shut off the valve at the LP 

Cylinder immediately.

The Propane (LP) cylinder must also be 

equipped with the following

 

A collar to protect the gas valve.

 

A shut-off valve terminating a LP cylinder valve 

outlet as specified in the American National 

Standard for Compressed Gas Cylinder Valve 

Outlets and Inlets Connections.

 

A safety relief valve having direct 

communications with the vapor space of the LP 

cylinder.

 

The heater must operate on vapor withdrawal 

from the operating cylinder.

The amount of Propane (LP) used with this 

heater varies. Both factors are

 

The amount of gas in the cylinder of LP.

 

The temperature of the LP tank and its 

surroundings.

 

Always keep LP cylinder fastened and upright.

 

Avoid tipping the LP cylinder on its side when 

connected to a regulator, since this may 

cause damage to diaphragm in the regulator.

 

Handle valves with care.

 

Never connect an unregulated LP cylinder to 

a construction heater.

 

DO NOT subject LP cylinder to excessive heat.

 

Tightly close the gas shutoff valve on the LP 

cylinder after each use. 

 

All fittings must be protected when 

disconnected from the LP cylinder.

 

Never store an LP cylinder inside a building or 

in the vicinity of an gas burning appliances.

Average Temp

(ºF)

80V-LPC-O

100 lb. cylinder

200V-LPC-O

100 lb. cylinder

32º

1

2

20º

1

2

10º

2

3

2

3

-10º

2

3

-20º

2

3

The table above shows the minimum number of 100 lb. LP 

cylinders required in cold weather. Your local LP dealer will 

help you select the proper LP supply System

Propane is safe to use when 

properly handled. Careless 

handling of the LP cylinder could result in a 

fire and or an explosion.

CAUTION

The disconnected tank must 

never be stored in a building, 

garage or any other enclosed area.

CAUTION

6

Summary of Contents for REM-200V-LPC-O

Page 1: ...THE MANUFACTURER DANGER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INS...

Page 2: ...nd approved for use as a construction heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other st...

Page 3: ...NDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of...

Page 4: ...a from the heater and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater Use only the regulator and hose assembly provided with this heater Inspect th...

Page 5: ...e 2 Specifications Model REM 80V LPC O REM 200V LPC O BTU 60 000 70 000 80 000 70 000 200 000 Fuel Consumption Lbs hr 2 8 3 2 3 7 3 2 9 3 Heat Settings 3 Variable Maximum Operating Hours 36 31 Require...

Page 6: ...from inside the heater See Figure 4 2 Remove all packaging protecting the heater during shipping Retain caps for covering the inlet connector and regulator hose fro storage 3 Attach three 3 screws to...

Page 7: ...National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of the LP cylinder The heater must operate on...

Page 8: ...ition turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connecti...

Page 9: ...SE to close it REM 200V LPC O 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder COUNTERCLOCKWISE until fully open 3 Set control valve to LIGHT LOW po...

Page 10: ...Storage Maintenance Always disconnect the heater from the LP cylinder before putting the heater into storage If for any reason the heater is to be stored indoors the tank MUST be disconnected from th...

Page 11: ...time for thermocouple to warm up 2 Gas pressure too low 3 Thermocouple needs replacing or loose 4 Control valve damaged 1 Keep Control Valve depressed for at least 30 seconds 2 Check cylinders for ade...

Page 12: ...R UNATTENDED WHILE BURNING CONNECTED TO A POWER SOURCE OR WHILE CONNECTED TO A FUEL SOURCE 2017 Pinnacle Climate Technologies Inc Convection Heater User s Manual Exploded View 11 Figure 8 REM 80V LPC...

Page 13: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for pr...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: