Printed in the Federal Republic of Germany
TR-Electronic GmbH 2018, All Rights Reserved
06/21/2018
TR - ELA - BA - DGB - 0028 - 00
Page 65 of 84
5.2.2 POWERLINK Status
LED 1
green
OFF
NMT_GS_OFF,
NMT_GS_INITIALISATION,
NMT_CS_NOT_ACTIVE
Flickering
NMT_CS_BASIC_ETHERNET
Single flash
NMT_CS_PRE_OPERATIONAL_1
Double flash
NMT_CS_PRE_OPERATIONAL_2
Triple flash
NMT_CS_READY_TO_OPERATE
ON
NMT_CS_OPERATIONAL
Blinking
NMT_CS_STOPPED
ON, red
POWERLINK error
5.2.3 ENCODER Status
LED 2
Description
OFF
- Voltage supply absent or too low
- Hardware error, measuring system defective
ON, green
Measuring system ready for operation (no error)
ON, red
Measuring system error occurred
Blinking, red
Teach-in mode active
5.2.4 Link/Data Activity - PORT1/PORT2
LED 3: PORT1
LED 4: PORT2
Link/Data Activity IN/OUT
Description
OFF
No Ethernet connection
ON (Link), green
Ethernet connection established
Blinking (Data Activity), yellow
Data transfer TxD/RxD