Commissioning
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 64 of 84
TR - ELA - BA - DGB - 0028 - 00
06/21/2018
5 Commissioning
5.1 Device description file
The XML-based XDD-file contains all information on the measuring system-specific
parameters and the operating modes of the measuring system. The XDD file is
integrated by the POWERLINK network configuration tool, in order to enable correct
configuration and commissioning of the measuring system.
The XDD file is called
"0x0000025C_TR-Electronic_LMC55-EPL.xdd"
.
Download:
www.tr-electronic.de/f/TR-ELA-ID-MUL-0028
5.2 Bus status display
The POWERLINK measuring system is equipped with four bicolour diagnostic LEDs.
For appropriate measures in case of error see chapter “Optical displays” page 82.
LED 1: POWERLINK Status
(red, green)
LED 2: ENCODER Status
(red, green)
LED 3: PORT1, Link/Data Activity (red, green)
LED 4: PORT2, Link/Data Activity (red, green)
Figure 10: POWERLINK diagnostic LEDs
5.2.1 Indicator states and flash rates
LED-Status
Indicator states and flash rates
ON
constantly ON
OFF
constantly OFF
Flickering
Blinking
Single flash
Double flash
Triple flash
Table 2: LED indicator states