6
B.1 Specification
°C
0
10
20
30
40
50
60
70
80
90
100
Ω
1000 1039 1077 1116 1155 1194 1232 1270 1308 1347 1385
Description
Electric specification::
Voltage
100 - 240 VAC +/- 10%
Mains frequency
50 - 60 Hz
Power consumption
0,5W - 2,5 W
Internal fuse
T2 A / 250 V slow blow
IP rating
IP40
El. protection class
II
Overvoltage category
II
Pollution degree
II
SRS2 TE
Mechanical relay, 460 VA (AC1), 460 W (AC3)
2 (R1, R2)
Mechanical relay, 3500 VA (AC2), 3500 W (AC3)
1(R3)
Pt1000 sensors, from -40 °C to +300 °C
3
Permissible cable length of sensors and accessories:
Collector sensor
<30 m
other Pt1000 sensors
<10 m
Mechanical relay
<10 m
Clock backup period
24
h
Permissible ambient conditions:
Ambient temperature:
for controller operation
0°C...40 °C
for transport/storage
0°C...60 °C
Air humidity:
for controller operation
max. 85% rel. humidity at 25 °C
for transport/storage
no moisture condensation permitted
Other specifications and dimensions:
Housing design
2-part, ABS plastic
Installation methods
wall installation, optionally panel installation
Overall dimensions
163 mm x 110 mm x 52 mm
Installation aperture dimensions
157 mm x 106 mm x 31 mm
Display
fully graphic display, 128 x 64
LED multicolour
Operation
4 entry keys
Temperature sensors:
B.2
Temperature resistance table for Pt1000 sensors: