Installation and Operation Manual RTC 12i  - www.regulus.eu

1. GENERAL INSTRUCTIONS

Read this manual carefully before operating and retain it for future reference. In case of loss, the 

manual can be downloaded in pdf format from http://www.regulus.eu/.

1.1. Related Documentation 

 

Instructions for installation and operation of the heating controller according to the selected  

 

application. Connection variants are shown in Chapter 2.

Instructions for installation and operation of components that belong to the equipment (hot  

 

water storage tanks, thermal stores, valves and actuators, etc.).

Heat Pump Commissioning Report - issued by an authorized person authorized by the service  

 organization.

1.2. Safety Instructions

Turn off the power with an omnipolar switch before doing any work on the product.

The heat pump must be connected to protective earth.

The product is classified as IP X4.

When handling the product with a hoist ring or similar device, make sure that the lifting  

 

equipment, eyebolts and other parts are not damaged. Never stand under the hoisted product.

Never jeopardise safety by removing bolted covers, hoods or similar.

Never jeopardise safety by deactivating safety equipment.

Any work on the product’s cooling system should be carried out by authorised personnel only.

The product’s electrical systems should only be installed and serviced by a qualified electrician.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or  

 

similarly qualified persons in order to avoid a hazard.

This device can be used by children from the age of eight years and above and by people  

 

with reduced physical, sensory or mental ability or lack of experience or knowledge if they  

 

have been taught, either with supervision or with the instructions provided, how to use the  

 

device safely and understand the risks involved. Children should not play with the device.  

 

Cleaning and maintenance should not be carried out by children without supervision.

If these instructions are not followed when installing, operating and maintaining the system,  

 

manufacturer’s commitment under the applicable warranty terms is not binding.

1.3. Cleaning & Maintenance

Use a wet cloth to clean the outer metal and plastic parts. Do not use abrasive cleaners or  

 solvents.

Check the condensate drain regularly (visual check).

The condensate tray is included in the delivery of the heat pump. The delivery also  

 

includes a heating cable intended for installation in a condensate tray. A heating cable  

 

for the condensate drain pipe (code 18491) can be ordered as an optional accessory.

Protect the air inlets and outlets from snow, fallen leaves and other dirt. Check them regularly,  

 

and remove dirt with a soft brush very carefully if needed.

The fan stops during defrosting. Water flows from the evaporator and hisses are heard. Steam 

 

 

may escape from the heat pump. After defrosting, the fan starts again and the heat pump  

 

returns to normal operation.

The heat pump is NOT subject to regular refrigerant leakage checks.

Summary of Contents for 17448

Page 1: ...www regulus eu RTC 12i RTC 12i EN RTC 12i Heat Pump Installation and Operation Manual ...

Page 2: ... water storage tank 4 2 2 Connection with a thermal store combination with other renewable heat sources 4 3 CONSTRUCTION READINESS INSTALLATION 4 3 1 Scope of supply 5 3 2 Installation preparation and transport 5 3 3 Minimum distances 6 3 4 Placement of the heat pump 7 3 5 Condensate drain 8 3 6 Pipe installation 9 3 7 Electrical wiring 9 4 COMMISSIONING 10 4 1 Initial start up 10 4 2 Troubleshoot...

Page 3: ...maged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This device can be used by children from the age of eight years and above and by people with reduced physical sensory or mental ability or lack of experience or knowledge if they have been taught either with supervision or with the instructions provided how to use the device sa...

Page 4: ...of underfloor heating without the possibility to be shut off For system control it is necessary to use an IR 14 RTC smart controller which controls the entire heating and hot water system It is equipped with an integrated web server permitting control through a web browser or via a smartphone or tablet with the IR Client application for Android and iOS 2 2 Connectionwithathermalstore combinationwi...

Page 5: ...2 G 1 M nipples incl gaskets 3 2 Installation preparation and transport The installation must be carried out by a qualified person in accordance with the applicable stan dards and all regulations concerning occupational safety must be observed The heat pump shall be transported and stored in an upright position only Check that the product has not been damaged in transit Report any transport damage...

Page 6: ...roof If the product is placed in an area where it will be exposed to particularly harsh weather conditions or if there is a risk of damage from snow falling from a roof the product can be installed underneath a small awning Follow the recommendations below when choosing a heat pump location Location make sure that the heat pump does not disturb you or your surroundings with noise avoid installatio...

Page 7: ...e wall it is important to verify its load bearing capacity Depending on the composition and thickness of the wall it is recommended to use a chemical anchor or a through wall anchor for installation The brackets are galvanized and the complete support is supplied including steel ropes ensuring its spatial rigidity Follow the instructions for the wall mounting brackets Prior to placing the heat pum...

Page 8: ... cable to the drain pipe is not included in supply and can be ordered as an optional accessory code 18491 The drain pipe can be run a to the ground to a frost free depth the outlet and the space around the pipe must be filled with crushed stone to ensure sufficient condensate drain the underground section of the pipe can be perforated b into the building in its sewage system the through wall passa...

Page 9: ...g pipeline and possibly also to the house structure it is recommended to run the braided hose loose in a slight bend When installing compensators and braided hoses follow the instructions in the separate Installation Manuals that will come with these products Continue after the braided hose with copper stainless steel or other pipes of suitable size The appropriate dimension of the pipe is prescri...

Page 10: ...erial or design defect the installation company will contact the supplier and repair the defect Always report the serial number of the heat pump indicated on the label on the back of the heat pump Air in system If you hear a raspy sound from the heat pump make sure that it is completely air bled If necessary top up the system to operating pressure If the problem persists call a technician to deter...

Page 11: ...5 Fan motor 18 Wiring box cover 31 Heating element 6 Connecting part 19 Electric wiring box 32 Condenser heating element 7 Rear of fan housing 20 Side cover panel 33 Four way valve 8 Support 21 Refrigerant collector 34 Electronic expansion valve sensor 9 Installation box 22 Bottom cover panel 35 High pressure sensor 10 Top cover panel 23 Liquid refrigerant sensor 36 Low pressure sensor 11 Finned h...

Page 12: ...sor hot gas sensor low pressure switch high pressure switch green yellow green yellow flow switch temperature sensor return temperature sensor flow temperature sensor suction gas sensor outdoor temperature sensor temperature sensor hot gas sensor low pressure sensor high pressure sensor PFC power factor correction red blue black condenser heater compressor heater 4 way valve transformer Compressor...