P36E-4 Zero Clearance Direct Vent Gas Fireplace
42
BATTERY INSTALLATION
Optional
WALL SWITCH
1)
Run up to 10' of wire through the right or
left side gas inlet opening. Be careful not
to damage wire.
Note: We recommend a maximum of 10'
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
2)
Connect the wire to a wall switch and install
into the receptacle box. Disconnect the
three way on/off switch box wires from
the attach Green and White wires from
the wireharness. Connect the wire from
the wall switch to the Green and White
as shown on wiring diagrams.
CAUTION
Do not wire millivolt
wall switch wire
to 120V wire.
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum
wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Optional
REMOTE CONTROL
Use the Regency
®
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1)
Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the
fi
replace to
that location.
2)
Connect the two wires to the gas valve. See
wiring diagrams. Optional wall switch GT/
GTM/GTMF using wire 0.584.907
CAUTION
Do not wire millivolt
remote control wires
to 120V wire.
3)
Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
1
8
GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
1) 4 AA batteries must be installed in the battery pack to operate the burner switch.
2) Install 2 AA batteries per side and connect as shown below. The battery pack will be located near the gas controls at the base of the unit.
INSTALLATION