44
Regency Gemfire™ Gas Fireplace
MAINTENANCE
FAN SERVICE
1)
Remove the faceplate by lifting it up off the hinges on the sides of the
firebox.
2)
Remove the door frame overlay by swinging out 45
o
from the bottom and
lift up and out.
3)
Remove the glass door.
b)
Remove the 3 screws shown below at the bottom of the glass
door
.
c)
Swing the door out 45
o
from the bottom and lift up and out.
8)
Remove 8 screws to remove the fan access panel cover - located on
the left hand side floor of the firebox.
Fan Access Panel
6)
After extenders have been removed. Remove the 2 screws that
secure the burner tray, at the base of the firebox.
7)
Slide the burner to the left and lift it out.
Location of screws securing burner
4)
Loosen 6 screws that secure the burner extenders. on burner tray,
located behind the burner on either side of the pilot assembly.
5)
Lift out the 2 burner tray extenders.
Burner tray extenders
Burner tray extenders
Burner tray
PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IT TURNED OFF.