36
Regency Gemfire™ Gas Fireplace
INSTALLATION
LOG SET INSTALLATION
Installation of Reflective Panels must be completed before installing the log set.
Read the instructions below carefully and refer to the images. If the
logs are broken do not use the unit until they are replaced.
Broken logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can
alter the unit's performance which is not covered under warranty.
Log kit # 476-930 contains the following pieces:
Part #
Description
A x 2
Log
B x 2
Log
C x 2
Log
D x 2
Log
476-103 x 12 Pin Clips
946-669
Platinum Embers
1)
Remove the following if already installed:
a) Faceplate
b) Glass Door
c) Pebbles
d) Glass Crystals
e) Stones
Note
: Aeration Setting is set at 1/2" from the factory. The following are recommended settings for NG and LP units when using the log set :
NG = 1/2"
LP = Full Open
2)
Attach the 12 pin clips to the bottom cover (not the burner) in the exact locations indicated by an X, as shown in Diagram 2 below.
Note: Front and back measurements originate from the centre line of burner.
Side measurements originate from front edge of the bottom cover (see Diagram 3).
Note:
Units may have dimples on the burner to indicate pin clip installation points.
If dimples are not present on the burner, follow the above directions.
Diagram 2
Diagram 1
A
B
C
D
D
C
B
A
Diagram 4
Diagram 3
3) Pin clips are attached to the lip edge of the bottom cover (not the burner) see diagrams 3 & 4.
Bottom Cover
Side measurements
from corner edge.
Lip Edge
Burner
All measurements along the front
and back edge originate from centre
line.
Centerline indicated by "V" cut out
on the rear edge of the burner.
Measurements to
centre of pins.
20-5/8
5-5/8
19-1/2
19
x
x
7-1/2
11-3/8
8-3/4
4-3/4
7-3/4
15-3/4
x
x
x
x
x
x
x
1-1/2
2
17
6
x
x
x
L
C
20-5/8
v
19-3/16
19-3/16
Back
Front