Combustible wall chimney connector pass-throughs
Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9
mm) minimum wall thickness clay liner, construct a wall pass-
through. The clay liner must conform to ASTM C315 (Standard
Specification for Clay Fire Linings) or its equivalent. Keep a
minimum of 12" (304.8 mm) of brick masonry between the clay
liner and wall combustibles. The clay liner shall run from the brick
masonry outer surface to the inner surface of the chimney flue
liner but not past the inner surface. Firmly grout or cement the
clay liner in place to the chimney flue liner.
Using a 6" (152.4 mm) inside diameter, listed, factory-built
Solid-Pak chimney section with insulation of 1" (25.4 mm) or
more, build a wall pass-through with a minimum 9" (228.6 mm)
air space between the outer wall of the chimney length and wall
combustibles. Use sheet metal supports fastened securely to wall
surfaces on all sides, to maintain the 9" (228.6 mm) air space.
When fastening supports to chimney length, do not penetrate the
chimney liner (the inside wall of the Solid-Pak chimney). The inner
end of the Solid-Pak chimney section shall be flush with the inside
of the masonry chimney flue, and sealed with a non-water soluble
refractory cement. Use this cement to also seal to the brick
masonry penetration.
Method A:
12" (304.8 mm) Clearance to Combustible Wall Member:
Minimum chimney clearance to brick
and combustibles 2" (51 mm)
Minimum clearance
12" (304,8 mm) of brick
Minimum 12" (304,8 mm)
to combustibles
Chimney connector
Fire clay liner
Masonry chimney
Ch
imn
ey Flu
e
Minimum chimney clearance to brick
and combustibles 2" (51 mm)
Minimum clearance
9" (229 mm)
Chimney connector
Nonsoluble
refactory cement
Sheet steel supports
Air Space
Solid-insulated listed
factory-built chimney length
Use chimney mfrs. parts to
attach connector securely
Masonry chimney
Chimney F
lue
Factory Built
Chimney Length
Chimney length
flush with inside of flue
Air space
9"(229 mm) min.
Method B:
9" (228.6 mm) Clearance to Combustible Wall Member:
EN
17
installation
Summary of Contents for Contura Ri50
Page 30: ...EN 30 5 6 8 mm wrench or use crescent wrench installation ...
Page 40: ...1 2 3 4 EN 40 Installing the firebox cladding installation ...
Page 41: ...7 5 6 8 EN 41 installation ...
Page 42: ...11 9 10 EN 42 installation ...
Page 50: ...EN 50 maintenance ...
Page 51: ...EN 51 Replace front glass First 2 1 Remove side glass maintenance ...
Page 52: ...EN 52 maintenance ...
Page 53: ...EN 53 Replace gasket door First 3 1 2 Remove side glass Remove front glass maintenance ...
Page 54: ...EN 54 maintenance ...
Page 55: ...EN 55 maintenance ...
Page 56: ...EN 56 maintenance ...
Page 57: ...EN 57 PRESS PRESS maintenance ...
Page 58: ...EN 58 maintenance ...
Page 59: ...EN 59 Remove gasket back 4 maintenance ...
Page 60: ...EN 60 maintenance ...
Page 61: ...EN 61 Remove door 5 maintenance ...
Page 62: ...EN 62 maintenance ...
Page 63: ...EN 63 maintenance ...
Page 65: ...EN 65 maintenance ...
Page 66: ...EN 66 maintenance ...
Page 67: ...391697 Assembled Door Spare part number EN 67 Replacement parts parts list ...
Page 68: ...EN 68 Replacement parts Left or Right parts list ...
Page 77: ...NOTES ...
Page 79: ......
Page 80: ...NOTES ...
Page 81: ...EN 81 notes ...
Page 82: ...EN 82 notes ...
Page 83: ......