7. Remove door by removing Phillips head screw on the left bottom
corner of door (see image). Then remove the four (4) 3/8" hex bolts
holding the glass.
8. Remove logs (see manual for details). Once logs are removed,
remove the front log deflector by lifting straight up.
9. Remove burner from unit by pulling burner tube up and out.
10. Remove rear deflector by removing one (1) Phillips head screw.
With the rear log deflector removed, this will allow you to remove
the left and right log stand. Remove two (2) Phillips head screws
on each log stand to remove.
11. With both left and right log stands removed, remove the perforated
burner tray by removing three (3) Phillips head screws in the front
and two hex head bolts one on each side of the perforated burner
tray. This will now expose the 6 Phillips head screws holding the
valve assembly.
12. Disconnect the ground wire from the left hand side of the valve tray,
and then remove the spark electrode wire (X3) and flame sense
wire (X2) from IFC Board.