Regency
®
CLASSIC™ C34E-11 Direct Vent Freestanding Gas Stove
|
19
installation
C34E-11
03.04.19
920-073
9.
Once the plastic caps have been removed, connect the fan wires
(white and black) to the power supply wires. Connect red-white and
black-black. See Diagram 7.
Tuck any loose wires neatly into plastic clip located on the underside
of the fan.
11.
Once the ground wire has been attached to the blower, route the
ground wire back to the IFC board and attach to Ground Lug located
on the left front of the unit. See Diagram 9.
Diagram 7
Diagram 9
Diagram 10
10.
After the wires have been connected attach the ground wire to the left
side of the blower (Diagram 8).
12.
Route the power cord through the rear of the unit and attach the strain
relief to the back of unit as shown in Diagram 10 (bottom heat shield
shown).