Regency Bellavista
®
B41XTCE -11 Gas Fireplace
| 17
installation
Mantel Clearances
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-
combustible board. The non-combustible mantel when installed at a lower overall height may not be lower than 6 inches
from the top of the fireplace opening.
Mantel Clearances
B41XTCE
A
B
C
D
From Top of
Fireplace Opening
32-11/16"
(830mm)
25-13/16"
(656mm)
22-1/16"
(560mm)
17-9/16"
(446mm)
Combustible
Mantel Clearances
2
0
12
6
4
8
10
0
Top of
Fireplace
Opening
12”
1"
7”
A
B
C
Non-combustible
Header
(steel stud)
on edge
14
To Floor
12
24
Inches
D
6”
Non-combustible
Standoff
Summary of Contents for Bellavista B41XTCE