Regency Bellavista
®
B41XTCE -11 Gas Fireplace
| 37
installation
Vertical terminations
Three (3) 90
o
Elbows (Rigid Pipe 5" x 8")
One 90
o
elbow = Two 45
o
elbows.
Option
V
V + V1
H + H1
With these options,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows is required.
A)
0' Min.
2' Min.
2' Max.
B)
1' Min.
3' Min.
2' Max.
C)
2' Min.
4' Min.
3' Max.
D)
3' Min.
6' Min.
4' Max.
E)
4' Min.
7' Min.
5' Max.
F)
5' Min.
8' Min.
6' Max.
G)
6' Min.
9' Min.
7' Max.
H)
7' Min
10' Min. 8' Max.
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use rigid pipe adaptor #770-994
V
H1
H
V1
Diagram 52