Regency Bellavista
®
B41XTCE -11 Gas Fireplace
| 15
installation
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label), after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
Locating Your
Gas Fireplace
1. When selecting a location for your fireplace,
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
ensure that the clearances are met.
2. The appliance must be installed on a flat,
solid, continuous surface For example a
wood, metal or concrete floor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3. The B41XTCE Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
Installation
Checklist
1. Locate appliance:
a) Room location (Refer to "Locating Your
Gas fireplace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantel Clearances (Refer to "Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2. Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to
"Unit Assembly Prior to Installation" Section).
Note: Must be done before installing unit into
place.
3. Install vent (Refer to "Venting" sections).
4. Make gas connections. Test the pilot. Must be
as per diagram (Refer to "Pilot Adjustment"
section).
5. Make electrical connections to receptacle
supplied with unit (recommended).
6. Install standard and optional features. Refer
to the following sections:
a. Plug AC adaptor into 120V receptacle
b. Install 4AA batteries into battery pack
(optional)
c. Inner Panels or Brick Panels (Required)
d. Log Set Installation
e. Standard Flush Door
f. Remote Control
g. Fan Installation (Optional)
7. Final check.
4. This appliance is Listed for bedroom instal-
lations using the standard Remote (millivolt
thermostat system). Some areas may have
further requirements, check local codes
before installation.
5. The B41XTCE Gas Fireplace are approved
for alcove installations, see "Clearances"
section for details.
6. We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations refer
to "Exterior Vent Termination
Locations" section.
Diagram 1
Summary of Contents for Bellavista B41XTCE
Page 63: ...Regency Bellavista B41XTCE 11 Gas Fireplace 63 notes ...
Page 68: ...68 Regency Bellavista B41XTCE 11 Gas Fireplace warranty ...
Page 69: ...Regency Bellavista B41XTCE 11 Gas Fireplace 69 notes ...
Page 70: ...70 Regency Bellavista B41XTCE 11 Gas Fireplace notes ...
Page 71: ...Regency Bellavista B41XTCE 11 Gas Fireplace 71 ...