Regency Bellavista
®
B41XTCE -11 Gas Fireplace
| 59
maintenance
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1. Check the Venting System for corrosion in
areas that are exposed to the elements. These
will appear as rust spots or streaks, and in
extreme cases, holes. These components
should be replaced immediately.
2. Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other
foreign material.
3. Check for evidences of excessive condensa-
tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fittings. It may
be caused by having excessive lateral runs,
too many elbows, and exterior portions of
the system being exposed to cold weather.
4. Inspect joints, to verify that no pipe
sections or fittings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
Log Replacement
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs
may create carbon build-up
and will severely alter the unit's
performance which is not covered
under warranty.
Glass Gasket
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
Door Glass
Your Regency
®
fireplace is supplied with high
temperature 5mm Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass (Part
#
940-383/P) is shipped already installed into the
door frame. Reinstall as per Glass Door Installation
in the "Glass Door Removal" section.
Maintenance Instructions
1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean paint
brush as the logs are fragile and easily dam-
aged.
2. Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a
gas fireplace glass cleaner. The glass should
be cleaned when it starts looking cloudy.
3. The heater is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency® uses StoveBright
Paint - Metallic Black #6309.
4. Make a periodic check of burner for proper posi-
tion and condition. Visually check the flame of
the burner periodically, making sure the flames
are steady; not lifting or floating. If there is a
problem, call a qualified service person.
5. The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
7. In the event this appliance has been serviced
check that the vent-air system has been properly
resealed & reinstalled in accordance with the
manufacturer's instructions.
8. Verify operation after servicing.
Summary of Contents for Bellavista B41XTCE
Page 63: ...Regency Bellavista B41XTCE 11 Gas Fireplace 63 notes ...
Page 68: ...68 Regency Bellavista B41XTCE 11 Gas Fireplace warranty ...
Page 69: ...Regency Bellavista B41XTCE 11 Gas Fireplace 69 notes ...
Page 70: ...70 Regency Bellavista B41XTCE 11 Gas Fireplace notes ...
Page 71: ...Regency Bellavista B41XTCE 11 Gas Fireplace 71 ...