City Series ACC40E
|
55
installation
City Series 40 ACB40E
06.10.20
1
920-206
LISTINGS AND CODE
APPROVALS
This Fan Kit has been approved for use with
ACV40E / ACB40E / ACC40LE / ACC40RE.
NOTE: ENERGY LABEL RATINGS DO
NOT REFLECT INSTALL OF OPTIONAL
FAN KIT.
Check with your local building code agency before
you begin your installation to ensure compliance
with local codes, including the need for "permits"
and follow-up inspections. If any problems are en-
countered regarding code approvals, or if you wish
clarification on any of the instructions contained
here, contact your local dealer.
OPTIONAL FAN DUCTING KIT INSTALLATION
GENERAL INFORMATION
The Fan Kit increases the effectiveness of your
fireplace by dispersing warm air from the fireplace
to remote locations in the same room or other
rooms in your home.
Up to two kits may be installed on the fireplace.
Important Installation Notes
1. The appliance installation must conform with local
codes and installation codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes.
3. This kit is tested and safe when installed in accord-
ance with this installation manual. Please read
all instructions before starting installation and
follow all instructions carefully during installation.
4. Installation of this kit must be performed by a
qualified service technician.
5. The Fan Kit must be installed only as specified.
Any modifications of the kit or components will
void the warranty and may cause a fire hazard.
6. Plan the location of the fireplace and the warm air
duct runs, see diagram 1 as a guide for possible
duct runs and locations.
Diagram 1: Guide for possible air duct runs
and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is
9.0m.
The Extension Kit contains a maximum of up to
4.5m. Please purchase the Fan Duct Extension
Kit to increase the 9.0m
MINIMUM FRAMING
CLEARANCES
*
Wall studs must be 407mm on center for mount-
ing fan housing.
* Fan Housing: Maintain a 6mm clearance from
fan housing to combustible material.
* Wall Registers must be 102mm above floor and
/ or 102mm below ceiling.
1. Determine the location of the air register/fan
housing assembly. Cut a 121mm x 406mm hole
between framing members (wall studs or floor
joists). Maintain a 6mm clearance from fan
housing to combustible material. See Framing
Clearances section.
MINIMUM FAN DUCT
CLEARANCES
The fan ducting requires a minimum of
25mm clearance to combustibles.
Minimum 102mm
from floor
Minimum 102mm
from ceiling
Maximum Duct Run: 9.0m
Kit Contains 4.5m
If you require more than 4.5m please purchase Fan
Duct Extension Kit.
NOTE:
Airflow through the duct system is affected
by the duct length and number of bends. Keep
the length and bends to a minimum to maximize
performance.
Item No.
Description
No
Description
1
240V Fan As-
sembly
7
Aluminum Flex 4.5m
2
Duct Flange-
Fan
3
Adapter Round
to Oval
8
Duct Flange-Stove
4
Angle Bracket
9
Sidewall Grille
5
Junction Box
10
Connector Clamp
6
Wall Adapter
Plate
NOTE: The fan kit (946-591) does not contain
any ducting. The optional extension duct kit (7
in the noted table) is 4.5 metres in length and
its part number is 946-596.
8
8
9
Optional Fan Ducting Kit Installation
Note:
The 656-995 HeatWave adapter and 946-596 Aluminum flex (4.5m) must be purchased separately.