City Series ACC40E
|
27
installation
Framing Dimensions (Left Corner)
NOTE:
Framing may be constructed of combustible material (ie. 51mm x 102mm) and does not require steel studs.
Note: A combined minimum of
774 square centimetres of open
area is required for the convection
air outlet to cool the enclosure.
Ensure clearances for Convection
Air Outlets are met.
See clearances ACC40LE/AC-
C40RE (single sided) in this manual
as there are different methods as to
how this can be achieved.
Note: This appliance must be in-
stalled on a level and solid surface
such as a plywood floor which must
be the full width and depth of the
appliance.
Framing
Dimensions
Description
ACC40LE
A
Framing Height
949mm
B*
Framing Width
1226mm
C*
Framing Depth
483mm
D
Unit Base to Top Enclosure (Min.)
1600mm
G
Flue Centerline Height
1429mm
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
*
The framing depth does not take into account plasterboard/timber or similar materials
against the back wall. The framing depth will need to change based on the thickness
of the materials.
(example: B - 1226 mm framing width +13 mm plasterboard = 1239 mm)
(example: C - 483 mm framing depth + 13 mm plasterboard = 496 mm)
*
*
Maximum material dimen-
sions 51mm x 102mm for
Header studs (installed
on edge and flat)
Summary of Contents for ACC40E City Series
Page 79: ...City Series ACC40E 79 notes ...
Page 85: ...City Series ACC40E 85 notes ...
Page 86: ...86 City Series ACC40E ...
Page 87: ...City Series ACC40E 87 notes ...