Manual
– TopCon TC.LAE
Installation and commissioning
42 / 56
2016-06-08
6.2.7.4.
Pump out the coolant of expansions reservoir
3
2
1
4
Fig. 26
Removing/ Mounting of the filling hoses.
Preparation:
Mount the filling hoses,
refer to chapter 6.2.7.3 , page 41.
The main switch is switched on, on the front side.
Switch position: “1“
The main switch is switched on, on the device front side.
The pump switch
-4-
is switched off,
on the rear side.
Switch position:”0”
Procedure: Pump out the coolant expansion reservoir
Switch on the pump switch
-4-
until no more coolant flows in the
vessel
-1-.
Switch
position: “1”.
Switch off the pump switch -
4-
.
Switch position: “0”.
Check the coolant level in the internal expansion reservoir on the
device front side. For the procedure, refer to 6.2.6.5, page 38.
If the coolant expansions reservoir is not empty, repeat the
pumping out procedure according the steps before.
If the coolant expansion reservoir is empty,
follow the following steps.
Switch off the device main switch on the device front side.
Switch position:
“0”.
Let the pump switch
-4-
in position :”1” (switched on)
Remove the filling hose,
refer to chapter 6.2.6.3, page 35.
Fasten the Allen screws in the filling block.
For the procedure, refer to chapter 6.2.6.2, page 34.
Wipe off the splashed coolant via the available absorbent cloth or
paper.