Manual
– TopCon TC.LAE
Installation and commissioning
35 / 56
2016-06-08
6.2.6.3.
Removing/ Mounting of the filling hoses
1
2
Fig. 21
Removing/ Mounting of the filling hoses.
Preparation:
Make the coolant fill-up set available with:
o
the coolant Mixture: 30 % coolant to water.
For further information about the coolant and the
necessary quantity, refer to chapter 9.2.2, page 50.
o
The funnel and the fill-up hoses.
Make a collection vessel available
Capacity:
1 l.
Make an absorbent cloth or paper available.
Remove the Allen screws,
refer to chapter 6.2.6.2 , page 34.
Procedure: Mounting the hoses for the filling up
Mount the blue filling hose
-1-
in the left side of the block.
The hose with its mounting nipple is part of delivery.
Mount the venting hose
-2-
in the left side of the filling block.
The hose with its mounting nipple is part of delivery.
Procedure: Removing of the hoses after the filling up
Remove the filling hose
-1-
from the left side of the block.
Empty the content of the venting hose
-2-
into the available
vessel.
Dispose the redundant coolant into the coolant reserve can.
Remove the filling hoses
-1-
and
-2-
.
For procedure, refer to chapter 6.2.6.3, page 35.
Keep on the hoses.
Wipe off the splashed coolant via the available absorbent cloth or
paper.