Manual
– TopCon TC.LAE
Installation and commissioning
27 / 56
2016-06-08
6.1.3.
Disposal with due care for the environment
Electrical equipment and packing material
Electrical equipment and packing material are too valuable for
household waste.
Ethylene glycol
Do not leave ethylene glycol undiluted and/or in larger
quantities into the groundwater, in waters or into drains.
On the disposal of electrical equipment, chemical substances and
packing material, comply with national laws.
6.1.4.
Case installation/delivery with case
TopCon TC.LAE devices are installed in standard cases or switch
cabinets either separately or in multi-unit systems.
In the standard design TopCon TC.LAE devices are intended to be
installed in s
tandard 19” cases and switch cabinets with an external air
flow. In this case they are placed on rails or shelves and fastened at the
points provided on the front panel.
1
1
Fig. 15
Fastening positions
-1-
of the TC.LAE.
Number of screws:
For 4 U devices typically: 4 x screws M6.
On installation in cases or switch cabinets, the following points are to be
noted:
On device installation pay attention to the device dimensions.
For further information on the dimensions,
see chapter 9.3.1, page 51.
Use robust rails or shelves
The cases for TopCon TC.LAE devices must be in contact over
the full installation depth.
Provide fastening holes in the switch cabinet for the fastening
positions
-1-
and fasten the device to the switch cabinet via its