Manual
– TopCon TC.LAE
Installation and commissioning
31 / 56
2016-06-08
6.2.4.
Liquid cooling
– device disconnection
2
1
3
4
5
Fig. 18
Disconnection of a coolant hose from the coolant standard interface
of the device.
Preparation:
Open-end wrench: 24 mm
Procedure:
Loosen the union nut
-1-
, by turning to the left via open-end
wrench.
Slide the nut backwards
-2-
on the coolant hose.
Pull away
-2-
the coolant hose from the nipple of the coolant
interface.
Take the union nut from the coolant hose
-3-
and tighten strongly
-5-
on the coolant interface, by turning to the right via open-end
wrench.
Push
-4-
the sealed rubber stopper into the connection fitting.
Remember, that a coolant rest may be in the device, so the
sealed rubber stopper must be strongly pushed in the connection
fitting, to avoid leaks.
Repeat the procedure for the other interface.
Emptying the coolant from the interface.
For further information about the procedure,
refer to chapter 6.2.7, page 39.