Page 57 of 106
Master
: This base station provides the master synchronization pulse for each
connected slave base station (without external GPS clock source).
Master with GPS Synchro
: This base station is connected to a GPS clock and
provides the master synchronization pulse for each connected slave base station.
Backup - Slave
: This slave base station acts as a backup if the master base station
fails to provide synchronization pulses. This feature operates with or without an
external GPS clock connection.
Slave
: This base station synchronizes its operations to the synchronization pulse
received from the Master or Backup Master base station.
Cell Range km
: (
*
) Enter the distance to the subscriber located the farthest distance from
the base station.
Disable RF
: Click
Disable RF
to disable the transceiver output. This is for test
purposes only. The base station terminal must be reset to restore operation of the radio
transmitter.
Save
: Click
Save
to save and apply the current settings. Settings not marked with a red
asterisk are effective immediately. Settings marked with a red asterisk (
*
) only become
only effective after resetting the terminal.
Cancel
: Click
Cancel
to restore all fields to the last saved values.
Default
: Click
Default
to change all fields to the factory values.