Red
MAX
™
Base Station
user manual
Doc. #70-00058-01-01-DRAFT
Proprietary Redline Communications © 2006
November
29,
2006
Page 36 of 106
SC Synchro Status
: Status of the base station time synchronization. Refer to the
RedMAX base station Installation Guidelines for a complete details of the
synchronization feature.
No Synch
- base station is not using synchronization.
Master with GPS Synchro
- base station is Master and is synchronized to an
external GPS clock.
Master
- base station is Master and is using internal clock.
Slave
- base station is Slave.
Backup Slave
- base station is Backup Slave and will assume Master operations if
Master is unavailable.
IDU Temperature Celsius
: Internal temperature of the indoor terminal.
ODU Temperature Celsius
: Internal temperature of the transceiver.
Power Supply Status
: Display the status of the power circuits.
acOnly
- Terminal is equipped with AC circuits only.
dcOnly
- Terminal is equipped with DC circuits only.
acDc
- Terminal is equipped with AC and DC circuits.
Fans Status
: Display the status of the system cooling fans.
oneFanOn
- A single cooling fan is operating.
twoFansOn
- Both cooling fans are operating.
Reference RSS
: Target value for average Received Signal Strength (RSS) for
subscribers. Set by operator in the Wireless Interface screen.
Interface
The interface panel provides statistics for the wireless interface (802.16), the data
Ethernet port Data), and the management (Mgmt) Ethernet port. Select the desired
interface and Click
Refresh
to update the screen.
Figure 16: Web - Monitoring - Status - Wireless Statistics Screen
Interface
: Click arrow in the menu box to select the desired interface:
802.16
- Wireless interface.